We have changed our name from Sound Isolation Store to IsoStore. Same great service and products, just a new domain! Please update your bookmarks and contact information.

Site Wide Discounts

  • 5% Off
    $300+ Purchase
  • 10% Off
    $1000+ Purchase
  • 15% Off
    $2000+ Purchase

Add your order to your cart to see your final price. Additional discounts for contractors, AVS Forum members and military. *Does not apply to all products.

  • GenieClip LB4 Perimeter Clip

Add to Cart Or Add To Your Project

  • Used on perimeter of ceiling or wall if backing is not available
  • Ships same day from Georgia
  • Cost To Ship: $10 (regardless of quantity)
  • Lead Time: 1-5 days

Site Wide Discounts

  • 5% Off
    $300+ Purchase
  • 10% Off
    $1000+ Purchase
  • 15% Off
    $2000+ Purchase

Add your order to your cart to see your final price. Additional discounts for contractors, AVS Forum members and military. *Does not apply to all products.

PRODUCT USE

The installation of resilient clips requires a clip within a few inches of the perimeter. There are times when the layout of the ceiling joists does not allow for proper backing near the perimeter. This is where the GenieClip LB4 is used. This perimeter clip will help to avoid extra labor and cost of adding in blocking or additional joists. The performance of the GenieClip LB4 is at the same level of the standard GenieClip.

Maximize the performance of the GenieClip system by adding resilience to the floor above. We recommend the use of GenieMat RST-02 for a low cost high performance underlayment. This will increase the IIC rating by at least 6 IIC points and the STC rating by at least 2-3 points.

ESTIMATING

Maintain the layout and spacing used in the rest of the ceiling or wall partition.

INSTALLATION

GenieClip LB4 Install Guide PDF 353KB

Use a #8 1-1/2" coarse thread screw for wood framing or #8 1" self tapping screw for metal framing. The standard spacing from clip to clip is a maximum of 48" with each row of clips spaced either 24" or 16" from each other. These rows require a GenieClip within 3" of the end of the run. This provides support for the furring hat channel and drywall attached to the channel. If backing is not available within 3" of the end of the run, then the GenieClip LB4 is used. For ceilings, the GenieClip LB4 attaches to the wall with the clip faced down and the long side of the L bracket flush with the nearest ceiling joist.

SOUND TESTS

Independent Sound Test Results
Type Assembly STC OITC IIC
Ceiling Wood joists, R-19 insulation, single 5/8" drywall direct to framing, no finish floor 43 - 32
Ceiling Wood joists, R-19 insulation, single 5/8" drywall on GenieClips, no finish floor 52 - 44
Ceiling Wood joists, R-19 insulation, double 5/8" drywall on GenieClips, no finish floor 54 - 51
Ceiling Wood joists, R-19 insulation, single 5/8" drywall on GenieClips, GenieMat RST-02 over 3/4" gypsum concrete, tile floors 55 - 55
Ceiling Wood joists, R-19 insulation, double 5/8" drywall on GenieClips, GenieMat RST-02 over sub-floor, tile floors 54 - 57
Retrofit
Ceiling
Wood joists, R-19 insulation, single 5/8" drywall on joists, single 5/8" drywall on GenieClips in retrofit with R-8 insulation, no finish floor 48 - -
Wall Wood studs, R-13 insulation, two 5/8" drywall total with GenieClips 57 38 -
Wall Wood studs, R-13 insulation, three 5/8" drywall total with GenieClips 61 44 -
Wall Wood studs, R-13 insulation, four 5/8" drywall total with GenieClips 64 49 -
Retrofit
Wall
Wood studs, R-13 insulation, single 5/8" drywall on each side, single 5/8" drywall on GenieClips in retrofit with R-8 insulation 48 31 -
Wall Wood studs, R-13 insulation, two 5/8" drywall total 37 28 -
Wall Wood studs, R-13 insulation, three 5/8" drywall total 39 30 -
Wall Double stud framing with 3" spacing, double R-13 insulation, four 5/8" drywall total 65 53 -
Wall Staggered stud framing, R-13 insulation, four 5/8" drywall total 47 43 -

PRODUCT SPECS

GenieClip LB4 Specs
Dimensions 2-1/2" wide x 1-3/4" tall x 4" length
Projection Up to 1-5/8" from structure with 7/8" channel
Weight .25 pounds
Minimum Pullout 108 pounds
Load Failure 445 pounds pullout with 25 gauge channel
Shore A Durometer 37 durometer